This item is an excellent condition used Fluke Fluke 1775 Power Quality Analyzer. Calibrated to NIST Traceable Standards on August 13, 2026. Includes hard case, x4 Fluke 1500-12 Flexi CTs (1500A, 12"), voltage test leads with clips, ground test lead with small clip, USB-C charger, traceable certificate of calibration, and 180 day warranty. All pictures are of the actual unit and accessories.

 

This item comes with a 6 Month (180 day) warranty. Every pre-owned unit we offer goes through meticulous inspection and NIST calibration to guarantee its reliability and durability.

 

We Calibrate your Test Equipment! Contact us for more information on Calibration by visiting stratatek.com/calibration

 

For customers in the USA, all purchases arrive cleared. ALL brokerage or customs fees are prepaid by us.  Your item arrives FOB destination.

 

International Buyers – Please Note: Import duties, taxes, and charges are not included in the item price or shipping cost. These charges are the buyer's responsibility. Please check with your country's customs office to determine what these additional costs will be prior to bidding or buying. For more information of clarification, please ask.

 

Will ship worldwide. We make our best efforts to get you the best shipping prices. Contact us for other international rates and we will be pleased to give you a quote. We accept VISA / Mastercard. Paypal is also accepted. Sales to within Canada are subject to 5% GST.  Ontario sales subject to 13% HST.

Fluke 1775 Power Quality Analyzer Three Phase PQA 1500A CTs NIST Calibrated

US$7,599.00Price
Quantity
  • Product Information

    • Automatically measure power and power quality parameters
    • Power system connection and instrument setup autocorrection
    • Instrument automatically detects error in voltage and current wiring, providing correction without rewiring
    • High resolution touchscreen
    • Capacitive touchscreen allows use with PPE (double gloved hands), providing clear results in seconds
    • Power quality health summary: automatically evaluate power quality inputs against the EN 50160 electrical standard, providing detailed troubleshooting of power quality problem areas
    • Harmonics: multiple methods of harmonic analysis provide users with the data they increasingly need with basic fundamental to 50 integer harmonics, 2 to 9 kHz for IEC61000-4-30 Annex A compliance and harmonics to 30 kHz harmonics to discover the effects of inverters on the network
    • Critical power quality data is captured as soon as you begin a session, without extensive setup or selections
    • Intuitive user interface makes it easy to navigate between measurement parameters like V/A/Hz, power, dips and swells, harmonics, or PQ health at the push of a button
    • Capture damaging high-speed transients so you can mitigate their effects before equipment fails
    • Analysis and reporting comes standard with Fluke Energy Analyze Plus software giving you the ability to create customized reports, or leverage built-in one-click reporting to industry standards like EN 50160, IEEE 519 and GOST 33073
    Voltage Inputs
    Number of Inputs 4 inputs, 3 phases and neutral referenced to PE (5 connectors)
    Measurement Category 1000 V CAT III/600 V CAT IV
    Maximum Input Voltage 1000 V rms/1000 V DC (1700 Vpk)
    Nominal Voltage Range Wye and single phase: variable (50 to 1000 V)
    Delta: variable (100 to 1000 V)
    IEC 61000-4-30 Class A compliance for the nominal voltages (Vdin) 100 to 690 V
    Input Impedance 10 MΩ between P-P and P-N, 5 MΩ between P-PE and N-PE
    Bandwidth DC to 30 kHz for PQ measurements, excluding transients
    Resolution 24-bit synchronous sampling
    Sampling Frequency 80 kS/second at 50/60 Hz
    Scaling 1:1, variable for use of potential transformers
    Voltage Transients
    Measurement Range ±8 kV
    Sampling Rate 1 MS/second
    Bandwidth DC to 1 MHz
    Trigger Adjustable trigger level
    Triggers on high-frequency components >1.5 kHz
    Resolution 14-bit synchronous sampling
    Current Inputs
    Current Inputs 4 inputs 3 phases and neutral, range selected automatically to attached sensor
    Bandwidth DC to 30 kHz
    Resolution 24-bit synchronous sampling
    Sampling Frequency 80 kS/second at 50/60 Hz
    Scaling 1:1 variable
    Input Voltage Clamp: 50 mV/500 mV rms; CF 2.8
    Rogowski coil: 15 mV/150 mV rms at 50 Hz, 18 mV/180 mV rms at 60 Hz; CF 4
    All at nominal probe range
    Input Impedance 11 kΩ
    Data Acquisition Voltage and Current
    Input Mains Frequency DC, 50/60 Hz ±15% (42.5 to 57.5 Hz, 51 to 69 Hz)
    Topologies 1-φ, 1-φ IT, split phase, 3-φ delta, 3-φ wye IT, 3-φ aron/blondel (2 element delta), 3-φ delta open leg, 3-φ high leg delta
    Data Storage 8 GB internal
    Memory Size Typical 10 logging sessions of 8 weeks with 1-minute intervals and 100 events
    The number of possible logging sessions and logging period depends on user requirements
    Real-time Accuracy Internal: 3 ppm (0.26 seconds per day, 8 seconds per month)
    NTP (internet time): depending on internet latency, typical <0.1 seconds absolute to UTC<br> GPS: <1 ms absolute to UTC