top of page

The Fluke 437-II is a Class A compliant three-phase power quality analyzer that help you locate, predict, prevent and troubleshoot problems in single phase and three phase power distribution systems. Great for Marine, Military, and Aero Applications. In addition to all the standard features of the Fluke 434-II, the Fluke 437-II offers additional features for the more demanding application.

  • Energy loss calculator: Classic active and reactive power measurements, unbalance and harmonic power, are quantified to pinpoint true system energy losses in dollars (other local currencies available)
  • Power inverter efficiency: Simultaneously measure AC output power and DC input power for power electronics systems using optional DC clamp.
  • PowerWave data capture: 435 and 437 Series II analyzers capture fast RMS data, show half-cycle and waveforms to characterize electrical system dynamics (generator start-ups, UPS switching etc.).
  • Waveform capture: 435 and 437 Series II models capture 100/120 cycles (50/60Hz) of each event that is detected in all modes, without set-up.
  • Automatic Transient Mode: 435 and 437 Series II analyzers capture 200 kHz waveform data on all phases simultaneously up to 6 kV.
  • Fully Class-A compliant: 435 and 437 Series II analyzers conduct tests according to the stringent international IEC 61000-4-30 Class-A standard.
  • Mains signaling: 435 and 437 Series II analyzers measure interference from ripple control signals at specific frequencies.
  • 400 Hz measurement: 437 Series II analyzer captures power quality measurements for avionic and military power systems.
  • Troubleshoot real-time: Analyze the trends using the cursors and zoom tools.
  • Highest safety rating in the industry: 600 V CAT IV/1000 V CAT III rated for use at the service entrance.
  • Measure all three phases and neutral: With included four flexible current probes with enhanced thin flex designed to fit into the tightest places.
  • Automatic Trending: Every measurement is always automatically recorded, without any set-up.
  • System-Monitor: Ten power quality parameters on one screen according to EN50160 power quality standard.
  • Logger function: Configure for any test condition with memory for up to 600 parameters at user defined intervals
  • View graphs and generate reports: With included analysis software.
  • Battery life: Seven hours operating time per charge on Li-ion battery pack.
Vrms (ac+dc) Measurement Range1 to 1000 V phase to neutral
Vrms (ac+dc) Resolution0.01 V
Vrms (ac+dc) Accuracy±0.1% of nominal voltage
Vfund Resolution0.1 V
Vfund Accuracy±0.1% of nominal voltage
Operating Temperature32 to 104°F (0 to 40°C); 104 to 122°F (40 to 50°C) excluding battery
Storage Temperature-4 to 140°F (-20 to 60°C)
Electro-Magnetic-Compatibility (EMC)EN 61326 (2005-12) for emission and immunity
InterfacesMini-USB-B, Isolated USB port for PC connectivity SD card slot accessible behind instrument battery