This item is a good condition used Megger 550005B Transformer Turns Ratio Tester. Calibrated to NIST traceable standards on September 18, 2023. Includes traceable Certificate of Calibration and 90 day warranty. All pictures are of the actual unit.

 

For customers in the USA, all purchases arrive cleared. ALL brokerage or customs fees are prepaid by us. Your item arrives FOB destination.

 

International Buyers – Please Note: Import duties, taxes, and charges are not included in the item price or shipping cost. These charges are the buyer's responsibility. Please check with your country's customs office to determine what these additional costs will be prior to bidding or buying.

 

For more information of clarification, please ask.

 

Will ship worldwide. We make our best efforts to get you the best shipping prices. Contact us for other international rates and we will be pleased to give you a quote. We accept VISA / Mastercard. Paypal is also accepted. Sales to within Canada are subject to 5% GST. Ontario sales subject to 13% HST.

Megger 550005B Transformer Turns Ratio Tester Megger TTR Calibrated

$3,349.00Price
  • Single-phase TTR Transformer Turns Ratio Test Set measures the turns ratio and exciting current of windings in power, potential and current transformers. Deviations in turns ratio readings indicate problems in one or both windings or the magnetic core circuit.

    The single-phase, hand-cranked model measures highly sensitive turns ratios of up to 129.99:1 with accuracy of ±0.1%. An optional auxilary transformer extends the ratio range to 329.99:1.
    The TTR set operates on the principle that the voltage ratio of the transformer at no load is practically equal to the true turns ratio.
    The major source of error in a transformer is a primary impedance drop due to magnetizing current, which is kept to a minimum by excitation at a fraction of rated voltage. By employing a design that meets both of these conditions along with the use of a null balance system, the turns ratio of a transformer can be determined accurately.
    When measuring the turns ratio of distribution and power transformers, the accuracy is well within 0.1%.

    APPLICATIONS
    The single phase model is primarily used for testing single-phase power and distribution transformers, for low-ratio readings up to 129.99:1, or up to 329.99:1 with an auxiliary transformer. It can be used to test three-phase transformers by connecting and testing each phase separately.

     