Offering CAT IV 600 V, the Megger MIT1025 (1001-944) is a compact, light 10 kV insulation resistance tester for the diagnostic testing and maintenance of high voltage electrical equipment. Enclosed in a tough case it is both smaller and lighter than its predecessor making it even easier to carry and store.
As well as measuring insulation resistance to 20 Teraohms, the MIT1025 also offers various diagnostic tests such as Polarization index, Dielectric Absorption Ratio, Step Voltage, Dielectric discharge and ramp testing.
Now equipped with a lithium ion fast rechargeable battery, the MIT1025 has a large, clear, easy to read, display making it equally suitable for use in both bright sunlight and poorly lit environments. Information displayed includes resistance, voltage, leakage current, capacitance, battery status and time constant. In addition, the elapsed time of the test is displayed constantly removing the need for separate timer.
Insulation Range, Analog | 100kΩ to 10TΩ |
Insulation Range, Digital | 10kΩ to 20TΩ |
Test Voltages | 500V, 1000V, 2500V, 5000V, and 10,000V |
User Defined Test Voltages | 100V to 1kV in 10V steps 1kV to 5kV in 25V steps 5kV to 10kV in 25V steps |
Accuracy | ±5% to 2TΩ, ±20% to 20TΩ |
Voltage Output Accuracy | +4% -0% ±10V of nominal test voltage at 1GW load |
Voltmeter Range | 30 to 660V AC/DC, 50/60Hz |
Voltmeter Accuracy | ±3% ±3V |
Frequency Range | 45 to 65Hz |
Short Circuit Current | 3mA nominal, max. power on all loads outperforming many 5mA testers |
Insulation Alarm | 100kΩ to 1GΩ |
Current Range | 0.01nA to 6mA |
Current Accuracy | ±5% ±0.2 nA at all voltages |
Capacitance Range (above 500V) | 10nF to 25µF (dependent on measurement voltage) |
Capacitance Accuracy | ±10% ±5nF |
Capacitor Charge | <5s per µF at 3mA to 10kV |
Capacitor Discharge | <500 ms/µF to discharge from 10,000V to 50V |