This item is a great condition used Rotek 800A Precision Wattmeter Calibrator. Calibrated to NIST traceable standards on July 20, 2026. *There is some slight damage to rear frame, please see all pictures.* Includes standard power cable, traceable certificate of calibration, and 180 day warranty. All pictures are of the actual unit and accessories.
This item comes with a 6 Month (180 day) warranty. Every pre-owned unit we offer goes through meticulous inspection to guarantee its reliability and durability.
We Calibrate your Test Equipment! Contact us for more information on Calibration by visiting stratatek.com/calibration
Any questions or clarifications, feel free to ask
Please see our other items! Visit Stratatek.com
Item is in stock and located in Texas.
International Buyers – Please Note: Import duties, taxes, and charges are not included in the item price or shipping cost. These charges are the buyer's responsibility. Please check with your country's customs office to determine what these additional costs will be prior to bidding or buying. For more information of clarification, please ask.
Will ship worldwide. We make our best efforts to get you the best shipping prices. Contact us for other international rates and we will be pleased to give you a quote. We accept VISA / Mastercard. Paypal is also accepted. Sales to within Canada are subject to 5% GST. Ontario sales subject to 13% HST.
Rotek 800A Precision Wattmeter Calibrator NIST Calibrated
Product Information
The Rotek 800A Precision Wattmeter Calibrator is a high-accuracy AC power and energy meter calibrator designed for calibrating wattmeters, watt-hour meters, power transducers, and other AC power measurement instruments. It generates precision low-distortion AC voltage and current with adjustable phase angle, allowing accurate simulation of real-world power conditions at various power factors. The 800A is widely used in calibration laboratories, utilities, and electrical test facilities as a transfer standard for power measurements.
Specifications and Info
- Voltage Output: 11 to 749 VAC RMS
- Current Output: 0.011 to 50 A AC
- Frequency: 50 Hz, 60 Hz, or 400 Hz
- Voltage Accuracy: ±(0.02% of reading + 0.001% of range)
- Current Accuracy: As low as ±0.025% of reading (range dependent)
- Adjustable Power Factor: Continuously variable from leading through unity to lagging
- Low Harmonic Distortion: Typically ≤0.05% (resistive loads)
- Resolution: 1 V (voltage); 0.001% of current scale