CAPTAN 12 is a modular device consisting of the following components:
- Power supply module (to handle variations in input voltage magnitude and frequency)
- Measurement module (to feature automatic selection of the appropriate measurement range)
- Inverter module (to provide fully controllable output signals for precise and repeatable test results)
- Touch screen LCD module (to monitor and control of the test process)
These modules can be easily replaced by our trained service representatives.
CAPTAN 12 supports classic line-frequency (50 or 60 Hz) dissipation factor testing and frequency-sweep diagnostics (1–500 Hz) to evaluate insulation condition on high-voltage equipment.
Built on a modular hardware architecture
CAPTAN 12 is designed for quick servicing and long-term maintainability. Individual modules can be replaced independently, reducing downtime and simplifying repairs. This approach also makes upgrades more practical as your testing needs evolve.
Wisegrid Energy CAPTAN 12 Capacitance and Power Factor Test Set 12kV
- High-voltage AC injection up to 12 kV RMS for field and lab insulation testing.
- Measure tan delta / power factor and capacitance with high accuracy (tan delta ±0.005%, capacitance ±0.05%).
- Dielectric Frequency Response (NB DFR) sweep 1–500 Hz for deeper insulation assessment beyond line-frequency DF.
- Modular device architecture, allowing flexible configuration and easy maintenance.
- Web-based software with Wi‑Fi support for fast test setup, guided wiring diagrams, and report-ready results.