| Measurement Ranges and Accuracy |
| Voltage |
DC:
99.99 V, ±(0.7% + 2 digits)
999.9 V, ±(0.7% + 2 digits)
AC:
0.05 to 99.99 V, ±(1% + 5 digits)
999.9 V, 50 to 500 Hz |
| VDF |
ACV:
0.05 to 99.99 V, 50 to 60 Hz ±(1% + 5 digits)
999.9 V, 50 to 60 Hz ±(1% + 5 digits)
ACA:
0.1 to 99.99 A, 50 to 60 Hz ±(2% + 5 digits)
999.9 A, 50 to 60 Hz ±(2% + 5 digits) |
| Current |
DC:
99.99 A, ±(2% + 0.5 A)
999.9 A, ±(2% + 5 digits)
AC: 0.10 to 99.99 A, 50 to 60 Hz ±(2% + 5 digits)
999.9 A, >60 to 400 Hz ±(2.5% + 5 digits) |
| Peak Hold |
ACV:
140 V, ±(3% + 15 digits)
1400 V, ±(3% + 15 digits)
ACA:
140 A, ±(3.5% + 15 digits)
1400 A, ±(3.5% + 15 digits) |
| Frequency |
20 to 99.99 Hz, ±(0.5% + 3 digits)
20 to 999.9 Hz, ±(0.5% + 3 digits)
0.02 to 9.999 kHz, ±(0.5% + 3 digits) |
| Total Harmonic Distortion ACA/ACV |
99.9%, ±(3% + 10 digits) |
| Harmonic Distortion |
H01–H12: 99.9%, ±(5% + 10 digits)
H13-H25A: 99.9%, ±(10% + 10 digits) |
| Inrush Current ACA |
99.99 A, ±(3% + 0.3 A)
999.9 A, ±(3% + 5 digits) |
| Watts |
DC:
9.999 kW (10 V, 5 A minimum), ±(3% + 0.05 kW)
99.99 kW (10 V, 5 A minimum), ±(3% + 0.5 kW)
999.9 kW (10 V, 5 A minimum), ±(3% + 10 digits)
AC:
9.999 kW (10 V, 5 A minimum), ±(3% + 10 digits)
99.99 kW (10 V, 5 A minimum), ±(3% + 10 digits)
999.9 kW (10 V, 5 A minimum), ±(3% + 10 digits) |
| Power Factor |
-1 to 0 to 1, ±3° ±1 digit |
| Resistance |
999.9 Ω, ±(1% + 5 digits)
9.999 kΩ, ±(1% + 3 digits)
99.99 kΩ, ±(1% + 3 digits) |
| Continuity |
999.9 Ω, ±(1% + 5 digits) |
| Diode |
0.4 to 0.8 V, ±0.1 V |
| Capacitance |
3.999 μF, ±(1.9% + 8 digits)
39.99 μF, ±(1.9% + 8 digits)
39.99 μF, ±(1.9% + 8 digits)
3.999 mF, ±(1.9% + 8 digits) |
| Measuring Rate |
3 times per second |
| Meter Data |
| Jaw Opening |
1.77" (45 mm) |
| Bluetooth Range |
32' (10 m) |
| Data Recording |
Available via METERLiNK app |
| Drop Test |
4' (1.2 m) |
| Category Rating |
CAT IV-600 V, CAT III-1000 V |
| General Specifications |
| Operating Ambient Temperatures and Relative Humidity |
32 to 50°F (0 to 10°C), non-condensing
50 to 86°F (10 to 30°C), ≤80% RH
86 to 104°F (30 to 40°C), ≤75% RH
104 to 122°F (40 to 50°C), ≤45% RH |
| Storage Temperature and Relative Humidity |
14 to 122°F (-10 to 50°C)
0 to 80% RH (batteries not fitted) |
| Temperature Coefficient |
0.2 x (specified accuracy)/°C, <18°C, >28°C |
| Operating Altitude |
6562' (2000 m) |
| Shock Vibration |
Random vibration per MIL‐PRF‐28800f Class 2 (5 to 55 Hz, 3 g maximum) |
| Pollution Degree |
2 |
| Power Requirements |
6 x 1.5 V AAA alkaline batteries |
| Battery Life |
50 hours with alkaline batteries (backlight, worklight, and Bluetooth off) |
| Auto Power Off |
Approximately 30 minutes |
| Certifications |
UL, CE, FCC, IC, UKCA, CSAUS |
| Complies with Safety Standards |
IEC 61010-1:2010, IEC 61010-2-032:2012, IEC 61010-2-033:2012 |
| EMC |
FCC: 47 CFR part 15 subpart B
CE:
EN IEC 61326-1:2021
EN IEC 61326-2-2:2021
EN 301 489-1 V2.2.3 (2019-11)
EN 301 489-17 V3.2.4 (2020-09)
RF:
ETSI EN 300 328 V2.2.2
EN 62479:2010
EN 50663:2017 |
| Dimensions |
10.87 x 3.98 x 1.97" (276 x 101 x 50 mm) |
| Weight |
1.43 lbs (0.65 kg), including batteries |