The Flir Si2-Pro helps you significantly lower costs associated with mechanical bearing issues and partial discharge on electrical equipment. It also enables you to drastically reduce leaks in your facilities, cutting down expenses related to compressed air and gas leaks. With the Si2 series, you'll experience the best-in-class performance, decision support, fleet management, and enterprise data integration available.
For specialized needs, you can choose from additional models: opt for the Si2-LD for advanced leak detection and mechanical fault detection applications or select the Si2-PD for your electric utility applications. Explore these models in the related products section below to find the perfect fit for your requirements.
FLIR Si2-Pro Acoustic Imaging Camera (No GPS)
Ordering Information
Please allow 2 - 3 weeks for this product to arrive.
This item comes with a 1 year warranty.
Specifications
Acoustic Measurement 124 low-noise MEMS microphones, real-time sound visualization Detection Threshold 20 kHz: -15 dB SPL
35 kHz: 4 dB SPL
50 kHz: 10 dB SPL
80 kHz: 36 dB SPL
100 kHz: 51 dB SPLBandwidth 2 to 130 kHz Directional Resolution From 1° up to 0.125° Operating Distance From 1' (0.3 m) up to 656' (200 m) Severity Assessment Automatic AI-based severity assessment including recommended actions onboard camera Leak Localization and Detection Automatic leak recognition including estimated leak size and annual cost Leak Rate Detection Threshold 0.0032 l/min from 2.5 m, 0.0044 l/min from 6 m Gases detected Detects all gases provided they are under sufficient pressure. Quantifies leak rate costs for compressed air, ammonia, argon, carbon dioxide, helium, hydrogen, methane, natural gas, and nitrogen Other Acoustic Analysis Modes Mechanical fault detection Digital Camera 12 MP color Camera Field of View 75° diagonal Video Frame Rate Camera: 60 fps
Acoustic image: 30 fps
Screen: 70 fpsZoom 8x digital zoom Video Image Resolution 1280 × 720 Display Size: 5" (127 mm), 1280 x 720
Resistive touch screen, TFT LCD, MIPI DSIIntegrated Flashlight LEDs, three modes off, normal and bright Analysis and Reporting Online: FLIR Acoustic Camera Viewer (cloud service)
Offline: FLIR Thermal Studio (desktop software)Communication and Data Storage Data transfer: USB memory stick
Camera software update: USB connection
Still image format: .nlz and .jpg
Video recording and format: Up to 5 minutes (.nlz format)
Storage, internal: 128 GB (SD card)
Storage, external: USB 8 GB, Cloud storage capacity is unlimited
Image annotations: GPS, image tags and comments connectionPower Supply Camera power input:
Nominal input voltage: 12 V DC
Maximum input: 17 V DC, 3.3 A (limited)
Battery:
Li-Ion rechargeable battery pack (RRC 2054): 14.4 V DC, 3.45 Ah, 49.68 Wh
Usage: Up to 2.5 hours (depends on ambient conditions and usage, needs to be retested and confirmed with final product)
Charge time: Approximately 2 hours
Maximum output: 16.8 V DC, 5 A
Battery charger:
Input: 19 to 26 V DC, 2.8 A
Maximum output: 17.4 V DC, 4.8 AEnvironmental Data Operating temperature range: 14 to 122°F (-10 to 50°C)
Storage temperature range: -4 to 122°F (-20 to 50°C) maximum 4 to 77°F (-20 to 25°C) recommended (determined by the battery)
Relative humidity: 0 to 90% recommended
EMC: CFR47 FCC part 15 subpart B
Radio: CFR47 FCC part 15 subpart C/E, ETSI EN 301 489-1/-17/-19, ETSI EN 300 328, ETSI EN 301 893
Protection class: IP54
Safety: IEC 62368-1Dimensions Camera: 7.2. x 10.8 x 6.5" (184 x 276 x 167 mm)
Battery: 3.3 x 3.03" (85 x 77 mm), RRC2504
Packaging: 19.3 × 14.4 × 7.5" (490 x 365 x 190 mm)Weight Camera: 2.64 lbs (1.2 kg)
Battery: 0.55 lbs (0.25 kg)
Camera + battery: 3.2 lbs (1.45 kg)
Packaging: 13 lbs (6 kg)Features
- Mechanical fault detection for early identification of bearing problems, preventing costly downtime
- Quantify leak rate and cost of industrial gas and compressed air leaks, to prioritize repair and calculate savings
- On-camera and in-software severity assessment and type classification of partial discharge (PD) issues
- Automatic frequency tuning, 8x zoom, 12 MP digital camera, GPS data integration, IP54 rating, and a QR code reader
- Fleet management functionality for efficient tool usage and maintenance across large-scale operations
- Detect, locate, classify and assess partial discharge faults, compressed air and gas, and identify bearing issues efficiently
- Intuitive, light weight, one handed operation requiring minimal training
- On-device partial discharge type and severity analysis with recommended actions
- On camera measurement and cost analysis for compressed air and common industrial gases including ammonia, hydrogen, CO2, methane, helium and argon
- Bearing assessment
- Provides a greater return on investment for ultrasound inspection because the ease of use does not require experienced, trained technicians to get meaningful results
- Market demand to expand inspections beyond finding compressed air leaks and high voltage, overhead component partial discharge
- MECH mode camera operation allows quick detection and measurement of bearing and other mechanical issues that can lead to costly production disruption or safety hazards (three metrics provided for mechanical fault measurement)
- Industrial gas quantification provides leak detection, leak rate and cost quantification for compressed air, methane, natural gas, ammonia, hydrogen, helium, and argon to find and prioritize repairs, and maximize return on investment
- Lights can make a big difference: This camera features dual LED lamps to illuminate nearby dark areas
Includes
- Industrial Acoustic Imaging Camera
- Neck Strap
- USB Memory Stick
- Hard Carrying Case
- 2 x Batteries
- Battery Charger
- 4 x Power Cables
- License Card: FLIR Si-series Plugin for FLIR Thermal Studio, Perpetual License
- Printed Documentation