top of page

This item is an excellent Like New condition used Fluke MDA-550 Motor Drive Analyzer. Calibrated to NIST traceable standards on Auguat 29, 2023.

 

Comes with all standard accessories including:

  • Hard Carry Case
  • x3 i400s AC Current Clamp
  • BC190 Charger/power Adapter
  • VPS421-G (grey/black) 150MHz 100:1 Voltage Probe Set
  • VPS421-B (blue/black) 150MHz 100:1 Voltage Probe Set
  • VPS421-R (red/black) 150MHz 100:1 Voltage Probe Set
  • VPS410-II-R (red/black) 500MHz 10:1 Voltage Ratio Probe Set
  • USB Cable
  • Shoulder Strap
  • Traceable Certificate of Calibration

 

This item comes with a 3 Month (90 day) warranty.  All functions are guaranteed to work or money will be refunded.

 

For customers in the USA, all purchases arrive cleared. ALL brokerage or customs fees are prepaid by us.  Your item arrives FOB destination.

 

International Buyers Please Note: Import duties, taxes, and charges are not included in the item price or shipping cost. These charges are the buyer's responsibility. Please check with your country's customs office to determine what these additional costs will be prior to bidding or buying. For more information of clarification, please ask.

 

Will ship worldwide. We make our best efforts to get you the best shipping prices. Contact us for other international rates and we will be pleased to give you a quote. We accept VISA / Mastercard. Paypal is also accepted. Sales to within Canada are subject to 5% GST.  Ontario sales subject to 13% HST.

Fluke MDA-550 Motor Drive Analyzer 4 Channel 500MHz Motor Shaft Harmonics

$5,499.00Price
  • The Fluke MDA550 Motor Drive Analyzer, 4 Channel, 500 MHz with Motor Shaft and Harmonics simplifies complex motor-drive troubleshooting with guided test setups and automated drive measurements that provide reliable, repeatable test results on three-phase and single-phase inverter type motor-drive systems. The new Fluke MDA-550 Motor-Drive Analyzers save time and eliminate the hassle of setting up complex measurements, while simplifying the troubleshooting process. Simply select a test and the step-by-step guided measurements show you where to make voltage and current connections, while the preset measurement profiles ensures data capture for each critical motor-drive section-from the input to the output, the DC bus, and the motor itself. The built-in report generator can quickly and easily generate as-found, and as-left reports.

    The MDA-550 measures input voltage and current to quickly see whether values are within acceptable limits by comparing the drive's nominal rated voltage to the actual supplied voltage. The system can then check the input current to determine if the current is within the maximum rating and the conductors are suitably sized. This model allows the user to check the voltage unbalance at the input terminals to ensure that the phase unbalance is not too high (> 6-8 %), and that the phase rotation is correct, as well as to check the current unbalance, as excessive unbalance may indicate a drive rectifier problem.

    Excessive harmonics are not just a threat to rotating machines but also to other equipment connected to the electrical power system.The MDA-550 visually displays the waveform shape for visual inspection to check whether the harmonic distortion is within an acceptable level and also offers a harmonics spectrum screen which shows both the total harmonic distortion and individual harmonics. This model also has three harmonic ranges, 1st to 51st Harmonics, 1 to 9 kHz and 9 kHz to 150 kHz giving the ability to detect any harmonic pollution problems.

    • Measures voltage, current, DC Bus voltage level and AC ripple, voltage and current unbalance and harmonics, voltage modulation, and motor shaft voltage discharges
    • 4 input channels for voltage and current signals
    • Maximum voltage with 10:1 or 100:1 probe: 1000 V
    • Maximum resolution with 10:1 or 100:1 probe: 1 mV
    • Full scale reading: 999 counts
    • Frequency Range: 1.000 Hz to 500 MHz
    • Extended harmonics measurements to identify the effects of low and high order harmonics on electrical power systems
    • Conduct guided measurements for motor-drive input, DC bus, drive output, motor input and shaft measurements with graphical step-by-step voltage and current connection diagrams
    • Use simplified measurement setup with preset measurement profiles to automatically trigger data collection based on the chosen test procedure
    • Create reports quickly and easily
    • Measure additional electrical parameters with full 500 MHz oscilloscope, meter and recording capability for complete range of electrical and electronic measurement on industrial systems