- Autorange measurements with automatic AC/DC detection.
- DC, AC TRMS, AC+DC TRMS voltage up to 690V.
- Low impedance voltage input to eliminate ghost voltage readings.
- DC, AC TRMS, AC+DC TRMS current by means of external transducer.
- Frequency of voltage and/or current.
- Resistance and continuity with buzzer.
- MIN/MAX/PEAK/HOLD functions.
- 6000 counts.
HT Instruments Jupiter Multifunction Multimeter to Test Electrical Safety
$609.00Price
Please allow 4-5 weeks for this product to arrive.
Includes 1 year manufacturer warranty.
DC Voltage Measurement range 0.0V ÷ 690.0V Resolution 0.1V Accuracy ±(0.5%reading + 2digits) AC TRMS, DC, AC+DC TRMS, LoZ Voltage Measurement range 0.5V ÷ 690.0V Frequency range 32Hz ÷ 1kHz Resolution 0.1V Accuracy ±(0.5%reading + 2digits) AC TRMS Current with Flexible clamp F3000U Measurement range 1A ÷ 3000A Basic resolution 0.01A Accuracy ±(0.5%reading + 2digits) AC TRMS, DC, AC+DC TRMS Current with Standard clamp Measurement range 1mV ÷ 1000mV Resolution 1mV Accuracy ±(0.5%reading + 2digits) Inrush current (DIRC) - Flexible clamp F3000U Measurement range 1A ÷ 3000A Basic resolution 0.01A Frequency range 42.5Hz ÷ 69Hz Accuracy ±(2.0%reading + 2digits) Peak response time 1ms Max RMS response times 16.6ms, 20ms, 50ms, 100ms, 150ms, 175ms, 200ms Inrush current (DIRC) - Standard clamp Measurement range 1mV ÷ 1000mV Resolution 1mV Frequency range 42.5Hz ÷ 69Hz Accuracy ±(2.0%reading + 2digits) Peak response time 1ms Max RMS response times 16.6ms, 20ms, 50ms, 100ms, 150ms, 175ms, 200ms Resistance and Continuity test Measurement range 0.0Ω ÷ 1999Ω Basic resolution 0.1Ω Accuracy ±(1.0%reading + 5digits) Buzzer sound R<30Ω Voltage / Current Harmonics Harmonic order DC, 1 st ÷ 25 th + THD% Frequency range 42.5Hz ÷ 69Hz Resolution 0.1V / 0.1A Basic accuracy ±(5.0%reading + 10digits) Phase rotation test with 1-wire method Measurement range 100V ÷ 690V Frequency range 42.5Hz ÷ 69Hz Test on RCD protection devices RCD type AC, A, General Trip-out time measurement (ms) / Trip-out current measurement (mA) L-PE voltage range 100V ÷ 690V Frequency range 42.5Hz ÷ 69Hz Trip-out time measurement IΔN selectable among 30mA, 100mA, 300mA Trip-out current measurement for IΔN of 30mA Overall earth resistance without RCD tripping L-PE voltage range 100V ÷ 690V Frequency range 42.5Hz ÷ 69Hz Test current <15mA Measurement range 1Ω ÷ 1999Ω Resolution 1Ω Accuracy 5.0%reading + 3Ω L-N, L-L, L-PE Loop / Line Impedance L-PE, L-N voltage range 100V ÷ 690V Frequency range 42.5Hz ÷ 69Hz Test current 100mA Measurement range 0.1Ω ÷ 199.9Ω Basic accuracy ±(5.0%reading + 3digits)