  • Autorange measurements with automatic AC/DC detection.
  • DC, AC TRMS, AC+DC TRMS voltage up to 690V.
  • Low impedance voltage input to eliminate ghost voltage readings.
  • DC, AC TRMS, AC+DC TRMS current by means of external transducer.
  • Frequency of voltage and/or current.
  • Resistance and continuity with buzzer.
  • MIN/MAX/PEAK/HOLD functions.
  • 6000 counts.

HT Instruments Jupiter Multifunction Multimeter to Test Electrical Safety

$609.00Price
Quantity
  • Please allow 4-5 weeks for this product to arrive.

    Includes 1 year manufacturer warranty.

     

  • DC Voltage
    Measurement range 0.0V ÷ 690.0V
    Resolution 0.1V
    Accuracy ±(0.5%reading + 2digits)
    AC TRMS, DC, AC+DC TRMS, LoZ Voltage
    Measurement range 0.5V ÷ 690.0V
    Frequency range 32Hz ÷ 1kHz
    Resolution 0.1V
    Accuracy ±(0.5%reading + 2digits)
    AC TRMS Current with Flexible clamp F3000U
    Measurement range 1A ÷ 3000A
    Basic resolution 0.01A
    Accuracy ±(0.5%reading + 2digits)
    AC TRMS, DC, AC+DC TRMS Current with Standard clamp
    Measurement range 1mV ÷ 1000mV
    Resolution 1mV
    Accuracy ±(0.5%reading + 2digits)
    Inrush current (DIRC) - Flexible clamp F3000U
    Measurement range 1A ÷ 3000A
    Basic resolution 0.01A
    Frequency range 42.5Hz ÷ 69Hz
    Accuracy ±(2.0%reading + 2digits)
    Peak response time 1ms
    Max RMS response times 16.6ms, 20ms, 50ms, 100ms, 150ms, 175ms, 200ms
    Inrush current (DIRC) - Standard clamp
    Measurement range 1mV ÷ 1000mV
    Resolution 1mV
    Frequency range 42.5Hz ÷ 69Hz
    Accuracy ±(2.0%reading + 2digits)
    Peak response time 1ms
    Max RMS response times 16.6ms, 20ms, 50ms, 100ms, 150ms, 175ms, 200ms
    Resistance and Continuity test
    Measurement range 0.0Ω ÷ 1999Ω
    Basic resolution 0.1Ω
    Accuracy ±(1.0%reading + 5digits)
    Buzzer sound R<30Ω
    Voltage / Current Harmonics
    Harmonic order DC, 1 st ÷ 25 th + THD%
    Frequency range 42.5Hz ÷ 69Hz
    Resolution 0.1V / 0.1A
    Basic accuracy ±(5.0%reading + 10digits)
    Phase rotation test with 1-wire method
    Measurement range 100V ÷ 690V
    Frequency range 42.5Hz ÷ 69Hz
    Test on RCD protection devices
    RCD type AC, A, General Trip-out time measurement (ms) / Trip-out current measurement (mA)
    L-PE voltage range 100V ÷ 690V
    Frequency range 42.5Hz ÷ 69Hz
    Trip-out time measurement IΔN selectable among 30mA, 100mA, 300mA
    Trip-out current measurement for IΔN of 30mA
    Overall earth resistance without RCD tripping
    L-PE voltage range 100V ÷ 690V
    Frequency range 42.5Hz ÷ 69Hz
    Test current <15mA
    Measurement range 1Ω ÷ 1999Ω
    Resolution
    Accuracy 5.0%reading + 3Ω
    L-N, L-L, L-PE Loop / Line Impedance
    L-PE, L-N voltage range 100V ÷ 690V
    Frequency range 42.5Hz ÷ 69Hz
    Test current 100mA
    Measurement range 0.1Ω ÷ 199.9Ω
    Basic accuracy ±(5.0%reading + 3digits)