top of page

This item is an excellent condition used Martel M2000 Precision Calibrator Millennium Series Model 2000 with 100DCV and 100mADC output. Calibrated to NIST traceable standards with full measured data report on July 4, 2025. Comes with standard power cable and traceable calibration certificate with data report. All pictures are of the actual unit.

 

This item comes with a 6 Month (180 day) warranty.  All functions are guaranteed to work or money will be refunded.

 

For customers in the USA, all purchases arrive cleared. ALL brokerage or customs fees are prepaid by us.  Your item arrives FOB destination.

 

International Buyers – Please Note: Import duties, taxes, and charges are not included in the item price or shipping cost. These charges are the buyer's responsibility. Please check with your country's customs office to determine what these additional costs will be prior to bidding or buying. For more information of clarification, please ask.

 

Will ship worldwide. We make our best efforts to get you the best shipping prices. Contact us for other international rates and we will be pleased to give you a quote. We accept VISA / Mastercard. Paypal is also accepted. Sales to within Canada are subject to 5% GST.  Ontario sales subject to 13% HST.

Martel M2000 Precision Calibrator Millennium Series Model 2000 Calibrated Data

Quantity
  • The Martel M2000 Bench Calibrator sets a new standard in lab calibrator value - the M2000 features the accuracy and stability of calibration sources costing twice as much - and provides useful features no other calibrator offers in its class! Despite its world-class performance and powerful operating features, the M2000 Calibrator is very simple to setup and use.

    • Superior calibration accuracy
    • Direct keyboard entry or cursor entry with decade control
    • Automatic standby function protects device under test
    • Nine (9) manual/automatic setpoints per output range
    • Tellurium-Copper binding posts (thermal EMFs to <1 uV)
    • Local or RS232 remote control
    • Optional IEEE-488 control available
    • Compatible with Fluke Met/Cal® software
  • DCV Ranges:                                  

    • 0 to 100.000 mV
    • 0 to 1.00000 V
    • 0 to 10.0000 V
    • 0 to 100.000 V

    Resolution:

    • 0 to 100 mV Range:  1 mV
    • 0 to 1 V Range: 10 mV
    • 0 to 10 V Range: 100 mV
    • 0 to 100 V Range: 1 mV

    Accuracy:

    • 0 to 100 mV Range: ±0.003% (30ppm) ± 3.0 uV
    • 0 to 1 V Range: ±0.003% (30ppm) ± 20.0 uV
    • 0 to 10 V Range: ±0.003% (30ppm) ± 200.0 uV
    • 0 to 100 V Range:  ±0.003% (30ppm) ± 2.0 mV

    Maximum Burden (≤1 Ohm output impedance)

    • 0 to 100 mV Range: 10 mA
    • 0 to 1 V Range: 10 mA
    • 0 to 10 V Range: 10 mA
    • 0 to 100 V Range1 mA

    Output Current:

    • Range:  0 to 100.000 mA
    • Resolution1 mA
    • Accuracy (% of reading):  ±0.01% ± 2 mA
    • Maximum Burden: 10 V

    Stability: 

    • Warm-up Time = 30 minutes to rated accuracy

    Temp Coefficient:

    • (≤18°C/>28°C):  10% of accuracy spec/°C
bottom of page