Temperature calibrator TP 3M165E.2i TP Premium // Multifunction // -35-165 °C // -31-329 °F
Multi-Function, Ø60 x 170 mm, Touchscreen Interface with Internal / External Reference Sensor, ±0.1~1°C 110-240V AC, 50/60 Hz, 3x USB PC-ports
With Integrated Electrical Measuring Instrument
***Linearization is required
TP Premium
The calibrators of the TP Premium series are characterised by their unparalleled performance and outstanding operating comfort. By means of the intuitive menu structure, all necessary inputs can be made quickly and easily. The large touch screen has plenty of room to display the reference, target and devices under test temperatures. At the end of a calibration process, the TP Premium provides the complete calibration certificate. The continuously growing bandwidth of supported temperature ranges supports an increasing number of temperature sensors on the market. They can be calibrated with a resolution of up to 0.001 °C / K and thus meet the highest requirements, e.g. of the food and pharmaceuticals industry
Temperature calibrators are used for the verification of the functionality and calibration of temperature measuring devices and temperature sensors. As the sole German manufacturer of these devices, we develop and produce our “Made in Germany” temperature calibrators with a special focus on long-term reliability and utmost accuracy in combination with easy operation. We can rely on more than 40 years of experience in doing this: SIKA’s first dry block temperature calibrator was launched all the way back in 1980. Every SIKA temperature calibrator is meticulously tested for accuracy and stability. This is attested by our standard calibration certificate, which we issue with every temperature calibrator, or by means of an optional DAkkS calibration certificate [German accreditation body]. This is to guarantee that you receive a perfect product which can be traced back to national and international temperature measurement standards.
TP 3M165E.2i- Highlights
- Patented control technology - Fastest stabilisation times on the market - Time savings of up to 50 %
- Four functions in one calibrator (dry block / calibration bath / infrared / surface)
- Large calibration volume / large calibration insert for simultaneous calibration of many devices under test
- Patented touch screen function for simple and convenient operation
- Automatic generation of the calibration certificate
- Optional as pharmaceutical and food industry version with stainless steel housing
- Accessories: device under test management with barcode scanner
- Available with integrated measuring instrument - TP 3M165E.2i
SIKA TP3M165E.2i Premium Temperature Calibrator Range: -35-165 °C
W033P413000GX0R2 External reference sensor TF 255-3-300
(-55-255 °C), straight versionW033P413000GXORI External reference sensor TF 255-3-300
(-55-255 °C), 90° angled versionW043P410400G3002 External reference sensor as cable sensor
(-50-150°C) (For Aseptic function
EPLIKSDE000)SleeveDB60170-A Dry Block - 2 bores: 1/8", 1/4" / [3.5, 6.5 mm] SleeveDB60170-B Dry Block - 3 bores: 1/8", 1/4" 1/2" /
[3.5, 6.5, 13.5 mm]SleeveDB60170-C Dry Block - 4 bores: 1/8" 3/16". 1/4". 3/8" /
[3.5, 5.0, 6.5, 9.5 mm]SleeveDB60170-D Dry Block - 7 bores: 1/8"x6, 1/4" /
[3.5(x6), 6.5 mm]SleeveDB60170-E Dry Block - 7 bores: 1/8"(x2), 3/16"(x2),
1/4"(x2), 3/8", [3.5(x2) 5.0(x2), 6.5(x2), 9.5 mm]SleeveDB60170-X w/o any drillings - Blank / Aluminum SleeveDB60170-S Customer Specified Sleeve Air-Shield Air-Shield Insert - w/o any drillings - Blank /
AluminumConsult Factory Air-Shield Insert - Customer Specified SleevelR60170 Infrared Insert SleeveSR60170 Surface insert / Aluminum Consult Factory Transition sleeve for calibrating sensors with
aseptic connectorsTubinsertMB60170 Tub Insert TP-Liquid-155C Calibration fluid (silicone oil),
10cSt (-35-155 °C), 1 literTP-Case Metal exterior w/ handle & foam cutout TP-Case & Trolley Case with wheels and telescopic handle
for Transport CaseTP-Barcode Barcode reader for easy recall & storage of
calibrationsDry-Block / Internal Linearization for Dry-Block function, using Internal
Reference Sensor. +/-0.2°CDry-Block / External Linearization* for Dry-Block function, using External
Reference Sensor, +/-0.2°CAir Shield/External Linearization* Dry block (Air Shield Insert) Aseptic/External Linearization** Dry block (for aseptic sensors] Bath/Internal Linearization for Liquid-Bath function, w/ Internal
Sensor & Tub Insert, +/-0.1°C
(Silicone oil 10 cSt (-35...155 °C)]Bath/External Linearization* for Liquid-Bath function, using External
Sensor & Tub Insert, +/-0.1°C
(Silicone oil 10 cSt (-35...155 °C)]Infrared/Internal Linearization for Infrared function, using Internal
Sensor, +/-0.5°C
Infrared/External Linearization* for Infrared function, using External
Sensor. +/-0.5°C
Surface/External Linearization* for Surface function, using External
Sensor, +/-1°C
*TF255-3-300 external sensor is needed
**W043P410400G3002 external sensor is needed