EV-TEST100 in combination with appropriate HT multifunction instrument simulates an electric vehicle connected to the charging station, allowing you to verify the EVSE full functionality and electrical safety. EV-TEST100 is able to test charging stations with charging modes 2 and 3 and Type 2 connector (European standard).

 

Thanks to the simulation of the vehicle’s status it is possible to verify that, starting from status B, the recharging column blocks the cable’s release.* * Only for charging stations equipped with an interlock system

In Stock now and ready to ship!

 

SIMULATION OF FAULT PE AND CP

Through the knob it is possible to carry out in a sequence the simulation of the interruption of the protective conductor (Fault PE) and the simulation of an error on the CP signal (Fault E).

 

MONITORING OF PWM OUTPUT

Through the dedicated output and the provided C100EV cable it is possible to verify the recharging mode and the encoding of the recharging current through the acquisition of the PWM signal (pulse width modulation).

 

VERIFICATION OF CONTROL PILOT

Through PP knob, rated currents of charging cables can be simulated, up to 63A.

 

VERIFICATION OF PROXIMITY PILOT

Possibility of simulating the various current capacitances of the recharging cable, up to 63A, when EV-TEST 100 is connected to the recharging station.* * Only for charging stations supporting this function

 

 

HT Instruments EV-TEST100 EVSE Adapter for Electric Vehicle Charger Testing EVS

US$589.00Price
Quantity
  • Ordering Information

    In Stock now and ready to ship!

    Please contact us for any additional information. 

    This item comes with a 1 year warranty from the manufacturer.

  • Technical Specifications

    Functions

    Use for EVSE charging stations Charging modes 2 and 3
    Test cable with connector Type 2 (IEC 62196-2)
    Vehicle simulation via Control Pilot (CP state) States A, B, C, D
    Simulating the current capacity of Proximity Pilot (PP state) NC, 13A, 30A, 32A, 63A
    Fault condition simulation on PE FAULT PE
    Diode simulation in short circuit FAULT E
    EVSE internal counter efficiency check LOAD
    Input voltage Max 415V AC, Phase-Phase, 50 / 60Hz
    External load L-N-PE 240V 50/60Hz, Max 10A AC
    CP signal PWM 12V
    External load protection Fuse FF 10A / 250V, 5x20mm
    Operating temperature 0°C ÷ 40°C
    Operating humidity <80&RH

    Guidelines

    •  IEC/EN60364-7-722
    •  IEC/EN61010-1
    •  IEC/EN61851-1