top of page

3671 series network analyzer provides frequency response, single-port, response isolation, enhanced response, full-dual port, electronic calibration etc. Offer various display formats, such as logarithmic amplitude, linear amplitude, phase, group delay, Smith chart and polar coordinates. 3671 series can accurately measure the amplitude frequency characteristics and phase frequency characteristics and group delay characteristics of microwave network.

3671 series vector network analyzer can be widely used in radar, communication, navigation and other fields, which are indispensable test equipment in national defense military industry and university scientific research.

 

  • Flexible Calibration Type, Compatible with Multiple Calibration Kits

    3671 series vector network analyzer provides different types of calibration.

    Users can choose calibration types based on the test requirements, which greatly facilitates testing on devices with different interfaces.

     

    •   Automated calibration

    •   Guided calibration

    (through response calibration, through response and isolation, single port calibration, enhanced response calibration, full two-port SOLT calibration, TRL calibration can be achieve by mechanical calibration kits)

    •   Electrical calibration (E-cal)

 

  • Multiple Windows to Display All Measuring Channels

    The analyzer possesses functions of multi-channel and multi-window display. 3671 series vector network analyzer supports up to 64 channels, maximum 32 measuring windows can be simultaneously displayed, and each window can simultaneously display up to 16 test traces, which makes the observation result more visible and the operation more convenient.

     

    The friendly GUI is simple and intuitive, easy to operate and improve test efficiency. Parameters can be entered quickly by using the activated input toolbar. Set limit line and segment scan value for production line to improve test efficiency.

 

  • Time Domain Analysis (TDA)

    Time-domain analysis refers to analyzing the stability, transient and steady-state performance of the control system according to the time-domain expression of the output quantity under a certain input.

     

    The 3671 series vector network analyzer can realize the switching between the frequency domain and the time domain of the measurement results, obtain the similarity and correlation of the signal waveform at different times, and obtain the characteristic parameters reflecting the operating state of the mechanical equipment. This function can be used to identify discontinuities in devices, fixtures or cables to realize accurate fault location.

 

  • TDR Option

    The advanced time-domain analysis option of the 3671 series vector network provides a virtual eye pattern and analysis function based on S parameter. The output unit of the simulation code type is used to generate the data bits of 0 and 1 change, convolve the simulation code type with the time-domain impulse response of the tested part, and obtain the virtual eye map after superposition.

     

    Depending on the different high-speed digital communication standards, TDR options can be used for high efficiency Pass/Fail tests using predefined eye pattern templates. And TDR option can apply Jitter, noise and other interference on the simulation eye pattern.

 

    Saluki 3671 Series Vector Network Analyzer VNA 100 kHz to 43.5 GHz

    Quantity
    • Order

      Please allow 4-5 weeks lead time for new product to arrive.

      For USA customers, all items will arrive FOB. Any taxes or tariffs are prepaid by us.

    • Features

      • Wide frequency coverage, frequency range from 100 kHz to 43.5 GHz
      • More optional intermediate frequency bandwidth, the maximum intermediate frequency bandwidth is up to 30MHz
      • Advanced calibration technology, vivid wizard calibration, flexible calibration type, compatible with multiple calibration kits
      • Offer various display formats, such as logarithmic amplitude, linear amplitude, SWR, group delay, Smith chart and polar coordinates
      • 12.1-inch 1280*800 high-resolution multi-touch screen, USB/LAN/GPIB/VGA/HDMI communication interfaces
      • One-button operation simplifies the measurement, easy to operation by advanced time domain options with added TDR impedance measurement, eye diagram analysis functions
    • Options

      Module No. Item Description
      3671C Vector Network Analyzer 100 kHz to 14 GHz
      3671D Vector Network Analyzer 100 kHz to 20 GHz
      3671E Vector Network Analyzer 100 kHz to 26.5 GHz
      3671G Vector Network Analyzer 10 MHz to 43.5 GHz
    • Specifications

      1. 3671C/D/E  
      Frequency Range

      3671C: 100 kHz to 14 GHz,

      3671D: 100 kHz to 20 GHz,

      3671E: 100 kHz to 26.5 GHz

      Frequency Resolution

      0.1 Hz

      Frequency Accuracy

      ±1×10-7 (23℃±3℃)

      Max. Output Power

      2-port

      •   100kHz – 10MHz: +5dBm        •   10MHz – 4GHz: +15dBm

      •   4GHz – 10GHz: +15dBm         •   10GHz – 14GHz: +10dBm

      •   14GHz – 20GHz: +9dBm         •   20GHz – 24GHz: +6dBm

      •   24GHz – 26.5GHz: 0dBm

      4-port

      •   100kHz – 10MHz: +3dBm        •   10MHz – 4GHz: +13dBm

      •   4GHz – 10GHz: +10dBm         •   10GHz – 14GHz: +4dBm

      •   14GHz – 20GHz: +3dBm         •   20GHz – 24GHz: -2dBm

      •   24GHz – 26.5GHz: -6dBm

      Power Sweep Range

      2-port

      •   100kHz – 10MHz: 40dB         •   10MHz – 20GHz: 45dB

      •   20GHz – 26.5GHz: 40dB

      4-port

      •   100kHz – 10MHz: 40dB         •   10MHz – 20GHz: 38dB

      •   20GHz – 26.5GHz: 34dB

      Dynamic Range

      2-port

      •   100kHz – 10MHz: 102dB         •   10MHz – 4GHz: 132dB

      •   4GHz – 10GHz: 133dB            •   10GHz – 14GHz: 125dB

      •   14GHz – 20GHz: 124dB          •   20GHz – 24GHz: 120dB

      •   24GHz – 26.5GHz: 115dB

      4-port

      •   100kHz – 10MHz: 102dB          •   10MHz – 4GHz: 132dB

      •   4GHz – 10GHz: 130dB             •   10GHz – 14GHz: 120dB

      •   14GHz – 20GHz: 119dB           •   20GHz – 24GHz: 115dB

      •   24GHz – 26.5GHz: 110dB

      Effective Directivity

      48dB (100kHz – 2GHz),  44dB (2GHz – 20GHz),  44dB (20GHz – 26.5GHz)

      Effective Source Match

      40dB (100kHz – 2GHz),  30dB (2GHz – 20GHz),  30dB (20GHz – 26.5GHz)

      Effective Load Match

      48dB (100kHz – 2GHz),  44dB (2GHz – 20GHz),  44dB (20GHz – 26.5GHz)

      Reflection Tracking

      ±0.04dB (100kHz – 100MHz),  ±0.05dB (100MHz – 20GHz),  ±0.05dB (20GHz – 26.5GHz)

      Transmission Tracking

      ±0.10dB (100kHz – 100MHz),  ±0.08dB (100MHz – 20GHz),  ±0.10dB (20GHz – 26.5GHz)

      Port Connection

      3.5mm (male)

         
      2. 3671G  
      Frequency Range

      10 MHz to 43.5 GHz

      Frequency Resolution

      0.1Hz

      Frequency Accuracy

      ±1×10-7 (23℃±3℃)

      Max. Output Power

      •   10MHz – 50MHz: +12dBm         •   50MHz – 250MHz: +13dBm

      •   250MHz – 1GHz: +13dBm         •   1GHz – 10GHz: +13dBm

      •   10GHz – 20GHz: +10dBm         •   20GHz – 35GHz: +8dBm

      •   35GHz – 43.5GHz: +3dBm

      Power Sweep Range

      •   10MHz – 50MHz: 30dB        •   50MHz – 10GHz: 33dB

      •   10GHz – 20GHz: 30dB        •   20GHz – 35GHz: 28dB

      •   35GHz – 43.5GHz: 28dB

      Dynamic Range

      •   10MHz – 50MHz: 90dB          •   50MHz – 250MHz: 98dB

      •   250MHz – 1GHz: 115dB         •   1GHz – 10GHz: 128dB

      •   10GHz – 20GHz: 122dB         •   20GHz – 35GHz: 118dB

      •   35GHz – 43.5GHz: 110dB

      Effective Directivity

      42dB (10MHz – 2GHz),  45dB (2GHz – 20GHz),  38dB (20GHz – 43.5GHz)

      Effective Source Match

      40dB (10MHz – 2GHz),  30dB (2GHz – 20GHz),  30dB (20GHz – 43.5GHz)

      Effective Load Match

      42dB (10MHz – 2GHz),  45dB (2GHz – 20GHz),  36dB (20GHz – 43.5GHz)

      Port Connection

      2.4mm (male)

         
      3. General  
      Number Of Measuring Ports

      standard 2 port, optional 4 port

      Peripheral Interface

      USB, GPIB, VGA, LAN, HDMI interface

      Display

      12.1-inch 16:10 screen (equipped with capacitive touch function)

      Power Consumption

      Maximum 300W

      Dimension

      426 (W) × 266 (H) × 400 (D) mm (no soles, no handles)

      516 (W) ×280 (H) ×490 (D) mm (include soles and handles)

      Weight

      3671C/D/E: max. 25kg

      3671G: max. 28kg

       

      For more information please click here.

    Related Products

    bottom of page