The SMNA06 is a compact, easy-to-integrate two-port vector network analyzer (VNA) with a frequency range covering 100 kHz to 6.5 GHz. It features low trace noise, a large dynamic range, and a high resolution bandwidth, making it widely applicable for testing RF and microwave devices such as filters, amplifiers, antennas, and cables.
The SMNA06 offers multiple calibration methods, including frequency response, response isolation, single-port, enhanced response, and full two-port calibration. It is built with various display formats, such as logarithmic amplitude, linear amplitude, standing wave ratio phase, group delay, Smith chart, and polar coordinates. Equipped with a standard RJ45 network interface, it enables fast and accurate measurement of the amplitude, phase, and group delay characteristics of the DUT S-parameters.This instrument can meet the testing requirements of wireless communications, cable television, education, radar systems, automotive electronics, and manufacturing facilities.
Saluki SMNA06 Vector Network Analyzer VNA 100kHz to 6.5GHz
Order
Please allow 4-5 weeks lead time for new product to arrive.
For USA customers, all items will arrive FOB. Any taxes or tariffs are prepaid by us.
Features
- Frequency range: 100kHz-6.5GHz
- Number of ports: two-port
- Measurement bandwidth: 10Hz-1MHz
- SSB phase noise: ≤-100dBc/Hz@10kHz 1GHz
- It features multiple display formats such as logarithmic/linear amplitude, standing wave ratio, polar coordinates, and Smith chart.
- It supports multi-window and multi-channel measurement, enabling rapid execution of complex test solutions.
- It features a compact size, making it suitable for system integration
Options
Main Machine
Module No. Item Description SMNA06 Vector Network Analyzer 100kHz-6.5GHz Options
Module No. Description / CK009 Mechanical calibration kit (4 SMA-type female calibration parts, DC-9000 MHz) CK009A Mechanical calibration kit (4 SMA-type female calibration parts, 3 SMA-type male calibration parts, DC-9000 MHz) Specifications
Measurement Range Port Impedance 50Ω
Port Connector N-type,female
Number Of Ports 2
Measurement Parameters S11, S21, S12, S22
Frequency Range 100kHz – 6.5GHz
Frequency Accuracy ±1.5ppm
Frequency Resolution 1Hz
Number Of Measurement Points 1-10001,default 201
Measurement Bandwidth 10Hz-1MHz(1, 2, 3, 5 steps)
Dynamic Range ≥105dB,110dB (typical)
Effectiveness Indicators Effective Directivity 40dB
Effective Source Matching 33dB
Reflection Tracking ± 0.05dB
Transmission Tracking ±0.05dB
Test Port Output Power Range -30dBm-+10dBm(≥5MHz)
Effective Source Matching ±2.5dB
Reflection Tracking 0.25dB
Transmission Tracking ≤-25dBc
Test Port Input Maximum Input level +20dBm
Maximum DC Input Voltage +35V
Reference Frequency Input REF OUT SMA-type female,10 MHz,output power +2 dBm-+8 dBm
REF IN SMA-type female, 10 MHz, output power +0 dBm – +3 dBm
Input Impedance 50Ω
Trigger Trigger In SMA-type female, TTL level
Trigger Out SMA-type female, TTL level
PC Host Computer Software Operating System Windows 7 and above
Computer CPU Frequency 2 GHz and above
Computer Memory 8 GB and above
Computer Interface LAN
General Data Dimensions(W×H×D) 160mm×45mm×245mm
Core Module Dimensions 100mm×40mm×150mm
Weight <1.9kg
Power Consumption <26W (+12V power supply)
Operating Temperature -10℃-+40℃
Storage Temperature -40℃-+70℃
Power Supply Input: 100V-240VAC 50/60Hz
Output: +12V 5A