top of page

S87236D/E/F/L USB peak and average power sensor is a diode-detection broadband power measurement instrument based on the USB 2.0 interface, which can realize accurate average power measurement, pulse power measurement with large dynamic range and CCDF statistical measurement analysis. The frequency range covers 50MHz to 67GHz, the highest power accuracy can reach 0.2dB, the video bandwidth is ≥30MHz, and the rise/fall time is ≤13ns.

S87236 series can flexibly expand the power measurement function of electronic measuring instruments and test systems, and is mainly used for field testing, production line testing and system integration.

    Saluki S87236 Series Peak/Average Power Sensor up to 67GHz

    Quantity
    • Order

      Please allow 4-5 weeks lead time for new product to arrive.

      For USA customers, all items will arrive FOB. Any taxes or tariffs are prepaid by us.

    • Features

      • High frequency up to 67GHz
      • Excellent dynamic range and accuracy
      • CCDF statistical measurement analysis
      • Internal zero calibration function
      • Built-in trigger input function
      • Automatic measurement function, including 16 pulse power and time parameters
      • Excellent measurement speed, up to 50,000 readings per second
      • Built-in radar and wireless presets
      • External trigger buffer measurement
      • Small size and easy to carry
    • Specifications

      Frequency Range

      S87236D: 50 MHz to 18 GHz,

      S87236E: 50 MHz to 26.5 GHz,

      S87236F: 50 MHz to 40 GHz,

      S87236L: 500 MHz to 67 GHz

      Power Range

      S87236D/F:

      Normal: 

      •   -30dBm to +20dBm (50MHz – 500MHz)

      •   -35dBm to +20dBm (≥ 500MHz)

      Average:

      •   -45dBm to +20dBm

      S87236L:

      Normal: 

      •  -35 dBm to +20 dBm (500 MHz – 40 GHz)

      •   -30 dBm to +20 dBm (40 GHz- 67GHz)

      Average:

      •  -45 dBm to +20 dBm (500 MHz-40 GHz)

      •  -40 dBm to +20 dBm (40 GHz-67 GHz)

       

      Max. Input Power

      +23 dBm (average power)

      +30 dBm (peak power, duration < 1μs)

      Rise/Fall time

      13ns

      Maximum Sampling Rate

      80MSamples/sec, continuous sampling

      VBW

      ≥30 MHz

      Single Capture Bandwidth

      ≥30 MHz

      Min.Pulse Width

      50ns

      Average Power Measurement Accuracy

      S87236D: ±0.20 dB (±4 .7%)
      S87236E: ±0.25 dB (±5 .9%)
      S87236F: ±0.30 dB (±7 .2%)
      S87236L: ±0.33 dB (±7 .9%)

      Maximum Capture Length

      1 s (down frequency)
      1.2ms (maximum sampling rate)

      Maximum Pulse Repetition Frequency

      10 MHz

      Max Voltage Standing Wave Ratio

      S87236D:
      1.20 (50 MHz≤f≤2 GHz)
      1.26 (2 GHz<f≤18 GHz)

      S87236E:
      1.20 (50 MHz≤f≤2 GHz)
      1.26 (2 GHz<f≤18 GHz)
      1.35 (18 GHz<f≤26 .5 GHz)
      S87236F:
      1.20 (50 MHz≤f≤2 GHz)
      1.26 (2 GHz<f≤18 GHz)
      1.35 (18 GHz<f≤26 .5 GHz)
      1.50 (26 .5 GHz<f≤40 GHz)
      S87236L:
      1.20 (500 MHz≤f≤2 GHz)
      1.26 (2 GHz<f≤18 GHz)
      1.35 (18 GHz<f≤26 .5 GHz)
      1.50 (26 .5 GHz<f≤40 GHz)
      1.70 (40 GHz<f≤67 GHz)

      Calibration Uncertainty

      S87236D:
      0.17 dB (4 .0%) (50 MHz ≤ f ≤ 10 GHz)
      0.19 dB (4 .5%) (10 GHz < f ≤ 18 GHz)
      S87236E:
      0.18 dB (4 .2%) (50 MHz ≤ f ≤ 1 GHz)
      0.19 dB (4 .5%) (1 GHz < f ≤ 18 GHz)
      0.22 dB (5 .2%) (18 GHz < f ≤ 26.5 GHz)
      S87236F:
      0.18 dB (4 .2%) (50 MHz ≤ f ≤ 1 GHz)
      0.19 dB (4 .5%) (1 GHz < f ≤ 18 GHz)
      0.22 dB (5 .2%) (18 GHz < f ≤ 26.5 GHz)
      0.24 dB (5 .7%) (26 .5 GHz < f ≤ 40 GHz)
      S87236L:
      0.19 dB (4 .5%) (500 MHz ≤ f ≤ 18 GHz)
      0.22 dB (5 .2%) (18 GHz < f ≤ 26.5 GHz)
      0.24 dB (5 .7%) (26 .5 GHz < f ≤ 40 GHz)
      0.29 dB (6 .9%) (40 GHz < f ≤ 67 GHz)

      Connector

      S87236D: N-Type (m)
      S87236E: 3.5mm (m)
      S87236F: 2.4mm (m)
      S87236L: 1.85mm (m)

      Time Base And Trigger  
      Horizontal Scale

      2 ns/div-100 ms/div

      Internal Trigger (typical)

      -20 dBm to +20 dBm

      Trigger Delay

      ± 1.0s (maximum)

      Trigger Holdoff

      1 μs-1 s

      Trigger Hysteresis

      0 dB-10 dB

      Input And Output  
      Trigger Input Interface

      MMCX connector is TTL-compatible and used for external trigger input

      Trigger Output Interface

      MMCX connector is TTL-compatible and used for trigger sync
      output

      Programmed Control Interface

      USB2 .0 interface, USB-TMC compatible

      Maximum Measurement Speed

      50,000 readings per second

      Product Characteristics  
      Display

      Host computer display

      Operating interface language

      Chinese/English

      Power supply requirement

      +5 V, 500 mA

      Operating temperature range

      -10°C – 50°C

      Saving Temperature

      -40°C – +70°C

      Weight

      ≤0 .30 kg (excluding accessories and packaging)

      Boundary Dimension (W×H×D)

      S87236D:  141.1mm×52.0mm×34.0mm
      S87236E:  133.9mm×52.0mm×34.0mm
      S87236F:  124.7mm×52.0mm×34.0mm
      S87236L:  124.7mm×52.0mm×34.0mm

      Recommended Calibration Cycle

      12 months

       

      Please click here for more information.

       

    • Options

      Module No. Item Description
      S87236D Peak and Average Power Sensor 50 MHz to 18 GHz
      S87236E Peak and Average Power Sensor 50 MHz to 26.5 GHz
      S87236F Peak and Average Power Sensor 50 MHz to 40 GHz
      S87236L Peak and Average Power Sensor 500 MHz to 67 GHz

    Related Products