top of page

The Uni-T MSO3054HD is a 12-bit, nine-in-one benchtop powerhouse. It serves as a 500MHz, 4-channel high-definition digital oscilloscope, logic analyzer, function/arbitrary waveform generator, spectrum analyzer, digital voltmeter, high-precision frequency counter, protocol analyzer, Bode plot analyzer, and power analyzer—all in a single instrument. Plus, it comes with up to 5 years of warranty coverage.

 

Overview

 

▪ Bandwidth: 500MHz Also available MSO3034HD 350MHz
▪ Vertical Resolution: 12-bit HD, 16-bit ERES
▪ 4 Analog Ch/16 Digital Ch, Logic Analyzer SW included (probes optional)
▪ Max Sample Rate: 5GSa/s per channel
▪ Memory Depth: 500Mpts per channel
▪ Max Capture Rate: 1,500,000 wfms/s per channel
▪ Arb Waveform Generator: Dual Channel 50MHz option
▪ 10.1-Inch UltraPhosphor3 Touchscreen Display
▪ 5-Year Warranty

 

Power Analyzer: (option) power quality, harmonics, switching loss, ripple wave, loop analysis, safety operation area
Spectrum Analyzer: up to 1GHz. Up to 4Mpts enhanced FFT, functions such as frequency setting, waterfall plot, detection setting, and marker are included
Bode Plot Analyzer: Option (also requires AWG option)
Bus Decode: Included: RS232/422/485/UART, I2C, SPI
Option: CAN, CAN-FD, FlexRay, LIN, SENT, MIL-STD-1553, ARINC429, Manchester, I2S/LJ/RJ/TDM (audio)
DVM/Frequency Counter: 7-bit
Measures up 54 measurement parameters
Mask limit testing
Web server (SCPI control, remote access wired and Wi-Fi)

UNI-T MSO3054HD 500MHz 4Ch Mixed Signal Oscilloscope

US$3,899.00Price
Quantity
  • Specifications

    Real 12-bit resolution, 500MHz, 4+16 CH, MSO ready, Max. 2.5GSa/s, Memory depth: 500 Mpts, 1,500,000 wfm/s, 10.1" Touch Screen

  • Optional Accessories

    Optional Accessories:

    Passive Probes:

    UT-P03 Scope Probe
    Passive Probe, Probe Attenuation: 10:1, Bandwidth (MHz): 60MHz, Voltage: 600Vpp

    UT-P04 Scope Probe
    Passive Probe, Probe Attenuation: 10:1, Bandwidth (MHz): 100MHz, Voltage: 600Vpp

    UT-P05 Scope Probe
    Passive Probe, Probe Attenuation: 10:1, Bandwidth (MHz): 200MHz, Voltage: 600Vpp

    UT-P06 Scope Probe
    Passive Probe, Probe Attenuation: 10:1, Bandwidth (MHz): 300MHz, Voltage: 600Vpp

    UT-P07 Scope Probe
    Passive Probe, Probe Attenuation: 10:1, Bandwidth (MHz): 500MHz, Voltage: 600Vpp

    UT-P08A Scope Probe
    Passive Probe, Probe Attenuation: 10:1, Bandwidth (MHz): 350Mhz, Voltage: 600Vpp

    UT-P20 High Voltage Scope Probe
    Passive Probe, Probe Attenuation: 100:1, Bandwidth (MHz): 250MHz, Voltage: 1500Vpp

    UT-P21 High Voltage Scope Probe
    Probe Attenuation: 1000:1, Bandwidth (MHz): 50MHz, Voltage: DC 15kVrms/AC 10kV

    UT-V23 High Voltage Scope Probe
    Passive Probe, Probe Attenuation: 100:1, Bandwidth (MHz): 100MHz, Voltage: 2000Vpp

    Current Probes:

    UT-P40 AC/DC Current Probe
    Voltage: 600Vrms, Output: 50mV/A, 5mV/A, Max A AC: N/A, MAX A DC: 60A, Frequency: DC~100kHz

    UT-P41 AC/DC Current Probe
    Voltage: , Output: 100mV/A, 10mV/A, Max A AC: N/A, MAX A DC: 100A, Frequency: DC~100kHz

    UT-P42 AC/DC Scope Probe
    Voltage: , Output: , Max A AC: , MAX A DC: 200A, Frequency: 150KHz

    UT-P43 Current Probe
    Output: 100mV/A, Max A AC: 20A, MAX A DC: 20A, Frequency: DC~25MHz

    UT-P44 Current Probe
    Output: 50mV/A, Max A AC: 40A, MAX A DC: 40A, Frequency: DC~50MHz

    Differential Probes:

    UT-P30 Differential Scope Probe
    Differential Probe, Probe Attenuation: 10:1/100:1, Bandwidth (MHz): 100MHz, Voltage: ±800Vpp

    UT-P31 Differential Scope Probe
    Differential Probe, Probe Attenuation: 10:1/100:1, Bandwidth (MHz): 100MHz, Voltage: ±1500Vpp

    UT-P32 Differential Scope Probe
    Differential Probe, Probe Attenuation: 100:1/1000:1, Bandwidth (MHz): 50MHz, Voltage: ±3000Vpp

    UT-P33 Differential Scope Probe
    Differential Probe, Probe Attenuation: 10:1/100:1, Bandwidth (MHz): 120MHz, Voltage: ±14KVpp

    UT-P35 Differential Scope Probe
    Differential Probe, Probe Attenuation: 50:1/500:1, Bandwidth (MHz): 50MHz, Voltage: 130VDC+PeakAC/1300VDC

    UT-P36 Differential Scope Probe
    Differential Probe, Probe Attenuation: 200:1/500:1, Bandwidth (MHz): 100MHz, Voltage: 560VDC+PeakAC/5600VDC

    Other Accessories:

    UT-ISOT Isolation Transformer
    Used for Bode Plot analysis. Requires scopes to have MSO2000-S-BODE or MSO3000CS-S-BODE option

    UT-M15 Logic Pod
    16Ch Logic Analyzer Probe Pod for MSO and UPO Series mixed-signal oscilloscopes

    BAG-B3 Carry Bag
    Taking your Uni-Trend Spectrum Analyzer and Digital Oscilloscope out into the field? Carry it safely from location to location with our padded carry bag.

    Oscilloscope Options

    MSO3000HD-ARINC429 Aerospace ARINC429 Serial Bus Trigger and Analysis Option
    MSO3000HD-AUDIO Audio Serial Bus Trigger and Analysis Option (I2S, LJ, RJ, TDM)
    MSO3000HD-AUTO Automotive Serial Bus Trigger and Decode Option (CAN, CAN-FD, LIN, FlexRay, SENT)
    MSO3000HD-AWG Dual-Channel 50 MHz Arbitrary Waveform Generator Option
    MSO3000HD-BND All Serial Bus Trigger and Decode Options (Including MSO3000HD-AUTO, MSO3000HD-AUDIO, MSO3000HD-MIL-STD, MSO3000HD-ARINC429, MSO3000HD-MANCH)
    MSO3000HD-BW2MT3M5 200MHz Upgrade to 350MHz Bandwidth
    MSO3000HD-BW2MT5M 200MHz Upgrade to 500MHz Bandwidth
    MSO3000HD-BW3M5T5M 350MHz Upgrade to 500MHz Bandwidth
    MSO3000HD-CAN Automotive Serial Bus Trigger and Analysis Option (CAN)
    MSO3000HD-CANFD Automotive Serial Bus Trigger and Analysis Option (CAN-FD)
    MSO3000HD-FLEX Automotive Serial Bus Trigger and Analysis Option (FlexRay)
    MSO3000HD-LIN Automotive Serial Bus Trigger and Analysis Option (LIN)
    MSO3000HD-MANCH Wireless Communication Serial Bus Trigger and Analysis Option (Manchester)
    MSO3000HD-MIL1553 Aerospace Serial Bus Trigger and Analysis Option (MIL-STD-1553)
    MSO3000HD-PWR Power Analysis Option
    MSO3000HD-SENT Automotive Sensor Bus Trigger and Analysis Option (SENT)
  • Order Information

    Please allow 2-3 weeks lead time for new product to arrive.

Related Products