Multifunction instrument for electrical installation safety testing, power quality analysis and EVSE safety testing.
MACROEVTEST is the new HT instrument to perform verification and control of electric car charging stations (EVSE) safety according to IEC / EN 61851-1 and IEC / EN60364-7-722 standards. Being a combined verification instrument, MACROEVTEST also carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type B, A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity. MACROEVTEST also allows measuring and saving environmental parameters (illuminance, temperature), leakage current and electric quantities such as voltage, current, power factor, power and harmonics on single-phase systems.
MACROEVTEST is provided with the innovative AUTO function: by selecting this function and only setting the value of RCD current, COMBI521 carries out tests of overall earth resistance, RCD tripping time and insulation resistance in a sequence. At the end of the test, the device shows all results with the indication of compliance or non-compliance with the standards with simple OK or NOT OK symbols.
The internal memory allows saving the measures and subsequently transfer them onto the PC through the optical/USB connection. Thanks to the brand new HTAnalysis App, free to download for iOS and Android systems, MACROEVTEST is capable of transferring measured and recorded data onto tablets and smartphones, thus giving the operator the possibility to customize and share through HTCloud the result of their tests.
AUTOMATIC EVSE SAFETY TEST
Check of the output voltage value
Continuity check of the protective conductor
Insulation resistance measurement
Check of the status:
- Standby (status A)
- Vehicle detected (status B)
- Mechanical interlock verification (status B)
- Ready (charging) (status C) with ventilation (status D)
- Fault simulation on the protective conductor (fault PE)
- Fault on CP signal (fault E)
Global earth resistance measurement
Measurement of RCD tripping time (type A, type B and type DD 6ma)
ELECTRICAL INSTALLATION SAFETY TEST
AUTOMATIC test (no-trip ground resistance, RCD tripping time, insulation resistance) in a sequence
Continuity of protective conductors with 200mA
Insulation resistance up to 1000V, with dielectric absorption ratio D.A.R. and polarization index P.I.
Polarity test
Type A, AC, B General and Selective RCD tripping time and current
Line/Fault impedance, Phase-Phase, Phase-Neutral, Phase-PE (also at high resolution with optional accessory IMP57)
Coordination of MCBs and fuses
Global earth resistance
Phase sequence and conformity measurement
Measurement of leakage current
Measurement of electrical parameters in single-phase installations (V, A, W, VAR, VA, PF)
Measurement of environmental parameters through external probes (HT52/05 and HT53/05)
GENERAL
Internal memory and PC connection
Wi-Fi connection to Android and iOS smartphones and tablets
HT Instruments MACROEVTEST Multifunction Installation, PQA, EVSE Tester
Ordering Information
Please allow 4-5 weeks for this product to arrive
This product comes with a 1 year manufacturer warranty
Included Equipment
- Calibration Report
- PR400 Probe
- 404-IECN Probe
- 5001-V Volatage Lead
- CO33X Leads
- 5004-IECN Clip
- UNIVERSALKITG3 Probes, Leads and Clips
- YABAT0003000 MI-MH Battery
- YABAT0004001 Battery Charger
- KITTERRNE Earth Resistance Leads
- C2006 USB and Downloadable Software
- 4004=-IECB Blue Probe
- 5001-N Black Lead
- 5001-B Blue Leads
- 5001-R Red Lead
- 404-IECV Green Probe
- 5004-IECB Blue Clip
- 5004-IECR Red Clip
- 5004-IECV Green Clip
- RCDX10 Leads
- PT400 Magnet
- VA507 Hard Carrying Case
- 404-IECR Red Probe
- EV-Test100
- SP-5100 Straps
Specifications
Sequence of tests for the verification of electric columns with EV-TEST100 adapter TRMS Insulation with test voltages 100, 250, 500, 1000VDC Continuity of protective conductors with 200mA Continuity of protective conductors with 10A With optional accessory EQUITEST Tripping time and current of RCDs type B, A, AC Standard, Selective and Delayed up to 1A Tripping time and current of RCDs with separate clamp jaws type B, A, AC Standard, Selective and Delayed up to 10A With optional accessory RCDX10 Non-trip earth resistance Earth resistance by voltammetric method Resistance of the single earth rods with clamp With optional accessory T2100 Ground resistivity by 4-wire method Loop/Line impedance, Phase-Phase, Phase-Neutral, Phase-PE With optional accessory IMP57 Measurement of percentage voltage drop on the line AUTO test (Non-trip ground resistance, RCD, Insulation) in sequence Contact voltage Phase sequence Leakage current with optional clamp meter Measurement of Voltage, Current, Active, Reactive, Apparent Power (1) Measurement of Cosphi, Power Factor (1) Voltage and current harmonics up to the 25th and THD% 25ª Protection category CAT IV 300V Measurement of environmental parameters (°C,°F, %RH, Lux) Test with remote lead PR400 Help on line on the display Internal memory for measured data saving Optical/USB serial port for PC connection Integrated WiFi connection and compatibility with HTANALYSIS App Size (LxWx H) (mm) 225 x 165 x 75mm Weight in grams (batteries included) 1.2kg