The HYDROCAL 1009 is a permanently installed multi-gas-in-oil analysis system with transformer monitoring functions. It individually measures, Moisture in Oil (H2O) and the key gases Hydrogen (H2), Carbon Monoxide (CO), Carbon Dioxide (CO2), Methane (CH4), Acetylene (C2H2), Ethylene (C2H4), Ethane (C2H6) and Oxygen (O2) dissolved in transformer oil.
As Hydrogen (H2) is involved in nearly every fault of the insulation system of power transformers and Carbon Monoxide (CO) is a sign of an involvement of the cellulosic / paper insulation the presence and increase of Acetylene (C2H2) and Ethylene (C2H4) further classifies the nature of a fault as overheating, partial discharge or high energy arcing. Oxygen (O2) can be a sign of excessive ageing or leakages within the sealing of hermetic transformers.
The device can serve as a compact transformer monitoring system by the integration / connection of other sensors present on a transformer via its optional analog inputs:
- 4 analog inputs 0/4 ... 20 mADC
- 6 analog inputs 0/4 ... 20 mAAC +20% or 0 ... 80 VAC +20% (configurable by jumpers)
MTE HYDROCAL 1009 Multi-Gas in Oil Analysis System with Transformer Monitoring
Ordering Information
Please allow 4 - 5 weeks lead time for this new product to arrive.
This product comes with a 1 year warranty from the manufacturer.
Features
- Individual measurement of Hydrogen (H2), Carbon Monoxide (CO), Carbon Dioxide (CO2), Methane (CH4), Acetylene (C2H2), Ethylene (C2H4), Ethane (C2H6), and Oxygen (O2) measurement
- Moisture in Oil (H2O) measurement
- Easy to mount on a transformer valve (G 1½" DIN ISO 228-1 or 1½" NPT ANSI B 1.20.1)
- Installation on the operational transformer without any operational interruption
- Advanced software (on the unit and via PC)
- Maintenance free system
- Communication interfaces ETHERNET 10/100 Mbit/s (copperwired / RJ 45 or fibre-optical / SC Duplex) and RS 485 to support MODBUS®RTU/ASCII, MODBUS TCP, DNP3 proprietary communication and IEC 61850 protocols
- Optional 2G/3G modem with external adhesive antenna
- Optional DNP3 serial modem for SCADA connection
- Optional IEC 61850 modem for SCADA connection
- Optional HV and LV bushing sensors for HV and LV bushing monitoring applications via communication interface
Transformer Monitoring Functions
- Voltages and Currents - (via voltage and current transformers / transducer)
- Temperature Monitoring - Bottom and top oil temperature, ambient temperature (via additional temperature sensors)
- Cooling Stage/Tap Changer Position - (e.g. via current transducer)
- Free configuration - Analog inputs can be free allocated to any additional sensor