top of page

The new HYDROCAL 1011 genX is a full-range / maintenance-free multi-gas online DGA solution combining proven near infrared (NIR) measuring technology with miniaturized gas sample production based on headspace principle (no membrane, negative pressure-proofed). It individually measures Moisture in oil (H2O) and the key gases Hydrogen (H2), Carbon Monoxide (CO), Carbon Dioxide (CO2), Methane (CH4), Acetylene (C2H2), Ethylene (C2H4), Ethane (C2H6), Oxygen (O2), Nitrogen (N2) and Propane (C3H8) dissolved in transformer oil.

MTE HYDROCAL 1011 genX Transformer Dissolved Gas and Moisture Analysis System

Quantity
  • Ordering Information

    Please allow 4 - 5 weeks lead time for this new product to arrive.

    This product comes with a 1 year warranty from the manufacturer. 

  • Features

    • Individual measurement of hydrogen (H2), carbon monoxide (CO), carbon dioxide (CO2), methane (CH4), acetylene (C2H2), ethylene (C2H4), ethane (C2H6), oxygen (O2), nitrogen (N2) and propane (C3H8)
    • Moisture in Oil (H2O) measurement  Easy to mount on a transformer valve (G 1½" DIN ISO 228-1 or 1½" NPT ANSI B 1.20.1)
    • Easy to mount on the operating transformer without any operational interruption
    • Maintenance-free near infrared measurement system with head-space gas extraction acc. IEC 60567
    • Advanced software (on the unit and via PC) with intuitive operation by 7” color TFT capacitive touchscreen, WLAN and Webserver operation from any smart phone, tablet or notebook PC
    • Communication interfaces ETHERNET 10/100 Mbit/s (copper-wired / RJ 45 or fibre-optical / SC Duplex) and RS 485 to support MODBUS® RTU/ASCII, MODBUS® TCP, DNP3, proprietary communication protocols and substation communication protocol IEC 61850 
  • Specifications

    Optional nominal voltages
    of auxiliary supply:
    120 V -20% +15% AC 50/60 Hz or
    230 V -20% +15% AC/DC 50/60 Hz or
    120 V +15% DC
    Power consumption: max. 320 VA
    Housing: Aluminium
    Dimensions: W 270 x H 270 x D 333.5 mm
    Weight: approx. 13.5 kg
    Operation temperature:
    (ambient)
    -55°C ... +55°C
    (below -10°C display function locked)
    Oil temperature:
    (in the transformer)
    -20°C ... +120°C
    Storage temperature:
    (ambient)
    -20°C … +65°C
    Oil Pressure: 0 … 800 kPa
    Connection to valve: G 1½" DIN ISO 228-1 or
    1½” NPT ANSI B 1.20.1