top of page

The ESA1 is a system of EMC tools for measuring the interference of assemblies and devices. The CS-ESA software allows the developer to quickly and comprehensively suppress interference affecting the DUT. Interference measurements taken during the development stage with ESA1 are proportional to the results from far-field measurements or from measurements with artificial networks. With the ESA1 tools disturbance sources can be localized, effects can be detected, and EMC measures individually determined. The effects of improvements implemented by ESA1 are proportional to the results from far-field measurements. ESA1 is designed for use at the developer's working place.

 

ESA1 Set consists of:

  • 1xCS-ESA set, ChipScan-ESA Software / CD-ROM
  • 1xHFW 21, RF Current Transformer
  • 1xHFA 21, RF Bypass
  • 1xZ23-1 set, Shielding Tent (900 x 500x 400) mm
  • 1xPA 203 BNC, Preamplifier 100 kHz to 3 GHz
  • 1xRF-B 0.3-3, H-Field Probe mini 30 MHz up to 3 GHz
  • 1xRF-B 3-2, H-Field Probe 30 MHz up to 3 GHz
  • 1xRF-E 02, E-Field Probe 30 MHz up to 1.5 GHz
  • 1xRF-E 05, E-Field Probe 30 MHz up to 3 GHz
  • 1xRF-E 10, E-Field Probe 30 MHz up to 3 GHz
  • 1xRF-R 0.3-3, H-Field Probe mini 30 MHz up to 3 GHz
  • 1xRF-R 3-2, H-Field Probe 30 MHz up to 3 GHz
  • 1xRF-R 50-1, H-Field Probe 30 MHz up to 3 GHz
  • 1xRF-R 400-1, H-Field Probe 30 MHz up to 3 GHz
  • 1xRF-U 2.5-2, H-Field Probe 30 MHz up to 3 GHz
  • 1xRF-U 5-2, H-Field Probe 30 MHz up to 3 GHz
  • 1xESA1 acc, Accessories
  • 1xESA1 case, System case
  • 1xESA1 m, ESA1 Set User Manual

Langer EMV ESA1 Set Emission Development System

Quantity
  • ESA1 Set User Manual

  • Specs

    HFW 21 RF Current Transformer  
    Frequency range 100 kHz - 1 GHz
    Continuous power rating  
    Current 10 A
    Dielectric strength 50 V
    Sizes (L x W x H) (135 x 32 x 28) mm
    HFA 21 RF Bypass  
    Capacitances 10 pF ... 100 nF
    Dielectric strength 50 V
    Shielding tent (900x500x400 mm)  
    Attenuated shielding 45 dB - 50 dB / 30 MHz - 1GHz
    Sizes (L x W x H) (900 x 500 x 400) mm
    Weight 12 kg
    Near Field Probes  
    Frequency range 30 MHz - 3 GHz
    CS-ESA software  
    Operating system Windows XP/Vista/7 (latest service packs)
    PA 203 preamplifier  
    Frequency range 100 kHz - 3 GHz
    Amplification 20 dB
    Supply voltage 12 V DC
    Current input 50 mA
    Max. input power +13 dBm
  • Order Info

    Please allow 2-3 weeks lead time for this new product to arrive.

Related Products

bottom of page